Why wet zones need a 30 mA RCD

Water changes everything

Dry skin resists electric current fairly well. Wet skin does not: the same touch that would tingle in a hallway can be fatal in a bathroom. That is why wiring standards treat bathrooms, kitchens and outdoor areas as wet zones.

Why exactly 30 mA

Currents above roughly 30 mA across the chest can make a heart fibrillate. A 30 mA RCD disconnects the circuit in under 40 ms — before the current does lasting harm. Higher-rated RCDs (100–300 mA) protect against fire, but not against shock.

What must be protected

  • All socket circuits in bathrooms, kitchens and outdoor areas.
  • Fixed appliances that combine water and electricity: water heaters, washing machines, dishwashers.

PlanMyPanel flags these circuits automatically, and the rule engine reports an error if any wet-zone circuit lacks 30 mA protection.

PlanMyPanel is a planning aid, not a substitute for a professional. Final assembly and connection must be reviewed and approved by a licensed electrician.

Built on the EU HD 60364 series and the CIS wiring regulations (PUE).